<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>Blog</title>
    <link>https://staging-www.stifirestop.com/blog</link>
    <description>Blog Description</description>
    <language>en-us</language>
    <pubDate>Fri, 13 Mar 2026 11:38:57 GMT</pubDate>
    <dc:date>2026-03-13T11:38:57Z</dc:date>
    <dc:language>en-us</dc:language>
    <item>
      <title>UL 2079 Test Standard Changes and SpecSeal® Track Top Gasket (TTG)</title>
      <link>https://staging-www.stifirestop.com/blog/news/ul-2079-test-standard-changes-and-specseal-track-top-gasket-ttg</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/ul-2079-test-standard-changes-and-specseal-track-top-gasket-ttg" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/image.jpg" alt="UL 2079 Test Standard Changes and SpecSeal® Track Top Gasket (TTG)" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Recently the UL STP (Standards Technical Panel) 1479 reviewed the UL 2079 test standard for construction joints specifically in regard to joint systems in which the firestop material when installed is not flush with the outer surface of the wall assembly utilizing a gasket type firestop rather than a traditional sealant or mineral wool and spray solution. This situation occurs mainly in head of wall conditions involving gypsum wall assemblies. &lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/ul-2079-test-standard-changes-and-specseal-track-top-gasket-ttg" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/image.jpg" alt="UL 2079 Test Standard Changes and SpecSeal® Track Top Gasket (TTG)" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Recently the UL STP (Standards Technical Panel) 1479 reviewed the UL 2079 test standard for construction joints specifically in regard to joint systems in which the firestop material when installed is not flush with the outer surface of the wall assembly utilizing a gasket type firestop rather than a traditional sealant or mineral wool and spray solution. This situation occurs mainly in head of wall conditions involving gypsum wall assemblies. &lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Ful-2079-test-standard-changes-and-specseal-track-top-gasket-ttg&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/ul-2079-test-standard-changes-and-specseal-track-top-gasket-ttg</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>STI’s “Zero” Spandrel System</title>
      <link>https://staging-www.stifirestop.com/blog/news/stis-zero-spandrel-system</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/stis-zero-spandrel-system" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Zero-Spandrel-System.jpg" alt="STI’s “Zero” Spandrel System" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;All vision glass curtain walls are becoming more&amp;nbsp;popular as architects are designing these walls to&lt;br&gt; provide&amp;nbsp;a modern and open concept for buildings. These buildings&amp;nbsp;are aesthetically pleasing and result in unique and upscale&amp;nbsp;designs. The difficulty firestopping all vision glass walls is&amp;nbsp;there rarely is an area to properly install the firestop system&amp;nbsp;and prevent it from being visible from the exterior of the&amp;nbsp;building. So the question is how we properly maintain the&amp;nbsp;life safety concern in the building while working within the&amp;nbsp;design of the building.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/stis-zero-spandrel-system" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Zero-Spandrel-System.jpg" alt="STI’s “Zero” Spandrel System" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;All vision glass curtain walls are becoming more&amp;nbsp;popular as architects are designing these walls to&lt;br&gt; provide&amp;nbsp;a modern and open concept for buildings. These buildings&amp;nbsp;are aesthetically pleasing and result in unique and upscale&amp;nbsp;designs. The difficulty firestopping all vision glass walls is&amp;nbsp;there rarely is an area to properly install the firestop system&amp;nbsp;and prevent it from being visible from the exterior of the&amp;nbsp;building. So the question is how we properly maintain the&amp;nbsp;life safety concern in the building while working within the&amp;nbsp;design of the building.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Fstis-zero-spandrel-system&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/stis-zero-spandrel-system</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>Autobonding Firestop Materials Facilitate Quick Repairs</title>
      <link>https://staging-www.stifirestop.com/blog/news/autobonding-firestop-materials-facilitate-quick-repairs</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/autobonding-firestop-materials-facilitate-quick-repairs" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Screen-Shot-2021-08-04-at-2_37_00-PM.png" alt="Autobonding Firestop Materials Facilitate Quick Repairs" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Sometimes the need to repair a firestop is&amp;nbsp;unavoidable. Inadvertent jobsite&lt;br&gt; mishaps are&amp;nbsp;perhaps the most common culprit that most&amp;nbsp;people would think of as a potential source of&amp;nbsp;damage to installed firestops. However, there is&amp;nbsp;often a need to conduct destructive sampling&amp;nbsp;tests of firestop materials to ensure compliance&amp;nbsp;with the appropriate tested system. The thickness&amp;nbsp;of the firestop material in this small specimen,&amp;nbsp;which was obtained from destructive testing,&amp;nbsp;is compared to a benchmark value to confirm&amp;nbsp;the firestop has been properly installed. Both&amp;nbsp;accidents and deliberate destructive testing can&amp;nbsp;create a firestop system that needs to be repaired.&amp;nbsp;Do we have to start from scratch and replace&amp;nbsp;the entire existing firestop or is there an easier&amp;nbsp;solution?&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/autobonding-firestop-materials-facilitate-quick-repairs" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Screen-Shot-2021-08-04-at-2_37_00-PM.png" alt="Autobonding Firestop Materials Facilitate Quick Repairs" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;Sometimes the need to repair a firestop is&amp;nbsp;unavoidable. Inadvertent jobsite&lt;br&gt; mishaps are&amp;nbsp;perhaps the most common culprit that most&amp;nbsp;people would think of as a potential source of&amp;nbsp;damage to installed firestops. However, there is&amp;nbsp;often a need to conduct destructive sampling&amp;nbsp;tests of firestop materials to ensure compliance&amp;nbsp;with the appropriate tested system. The thickness&amp;nbsp;of the firestop material in this small specimen,&amp;nbsp;which was obtained from destructive testing,&amp;nbsp;is compared to a benchmark value to confirm&amp;nbsp;the firestop has been properly installed. Both&amp;nbsp;accidents and deliberate destructive testing can&amp;nbsp;create a firestop system that needs to be repaired.&amp;nbsp;Do we have to start from scratch and replace&amp;nbsp;the entire existing firestop or is there an easier&amp;nbsp;solution?&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Fautobonding-firestop-materials-facilitate-quick-repairs&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/autobonding-firestop-materials-facilitate-quick-repairs</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>IBC Slab Edge Perimeter Fire Containment Requirements: A-Voiding a Misunderstanding</title>
      <link>https://staging-www.stifirestop.com/blog/news/ibc-slab-edge-perimeter-fire-containment-requirements-a-voiding-a-misunderstanding</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/ibc-slab-edge-perimeter-fire-containment-requirements-a-voiding-a-misunderstanding" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Picture2-3-1.png" alt="IBC Slab Edge Perimeter Fire Containment Requirements: A-Voiding a Misunderstanding" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;The 2021 International Building Code® was recently published.&amp;nbsp; Section 715 on “Joints and Voids” was refined to make it easier to understand the requirements.&amp;nbsp; Section 715.4 addresses the exterior wall/slab edge intersection.&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/ibc-slab-edge-perimeter-fire-containment-requirements-a-voiding-a-misunderstanding" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Picture2-3-1.png" alt="IBC Slab Edge Perimeter Fire Containment Requirements: A-Voiding a Misunderstanding" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p&gt;The 2021 International Building Code® was recently published.&amp;nbsp; Section 715 on “Joints and Voids” was refined to make it easier to understand the requirements.&amp;nbsp; Section 715.4 addresses the exterior wall/slab edge intersection.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Fibc-slab-edge-perimeter-fire-containment-requirements-a-voiding-a-misunderstanding&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/ibc-slab-edge-perimeter-fire-containment-requirements-a-voiding-a-misunderstanding</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>The Burn Newsletter – Fall 2021 Wrap Up</title>
      <link>https://staging-www.stifirestop.com/blog/news/fall-2021</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/fall-2021" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Summer-2021-Cover-1-1-1.jpg" alt="The Burn Newsletter – Fall 2021 Wrap Up" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p style="text-align: left;"&gt;&lt;strong&gt;In this issue:&lt;a href="https://indd.adobe.com/view/2a9b2fd9-0025-4fb8-a693-6ef29935d47f"&gt;&lt;/a&gt;&lt;br&gt; &lt;/strong&gt;&lt;/p&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/fall-2021" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Summer-2021-Cover-1-1-1.jpg" alt="The Burn Newsletter – Fall 2021 Wrap Up" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;p style="text-align: left;"&gt;&lt;strong&gt;In this issue:&lt;a href="https://indd.adobe.com/view/2a9b2fd9-0025-4fb8-a693-6ef29935d47f"&gt;&lt;/a&gt;&lt;br&gt; &lt;/strong&gt;&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Ffall-2021&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/fall-2021</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>Rich Walke – Creative Technology Inc.</title>
      <link>https://staging-www.stifirestop.com/blog/news/rich-walke</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/rich-walke" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/lw0cXrT8MaTGXHCec-zUVhHN-Dec-07-2023-05-25-52-6796-PM-Mar-02-2024-03-27-50-0774-PM-Mar-13-2026-11-32-24-8009-AM.jpg" alt="Rich Walke – Creative Technology Inc." class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;div style="width: 100%; height: 200px; margin-bottom: 20px; border-radius: 6px; overflow: hidden;"&gt; &amp;amp;amp;amp;amp;lt;span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start"&amp;amp;amp;amp;amp;gt;﻿&amp;amp;amp;amp;amp;lt;/span&amp;amp;amp;amp;amp;gt; 
&lt;/div&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/rich-walke" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/lw0cXrT8MaTGXHCec-zUVhHN-Dec-07-2023-05-25-52-6796-PM-Mar-02-2024-03-27-50-0774-PM-Mar-13-2026-11-32-24-8009-AM.jpg" alt="Rich Walke – Creative Technology Inc." class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;div style="width: 100%; height: 200px; margin-bottom: 20px; border-radius: 6px; overflow: hidden;"&gt; 
 &lt;iframe style="width: 100%; height: 200px;" src="https://player.captivate.fm/episode/c832bbcc-d634-4bab-aaac-8512aecee655" frameborder="no" seamless&gt;&amp;amp;amp;amp;amp;lt;span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start"&amp;amp;amp;amp;amp;gt;﻿&amp;amp;amp;amp;amp;lt;/span&amp;amp;amp;amp;amp;gt;&lt;/iframe&gt; 
&lt;/div&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Frich-walke&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/rich-walke</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>Firestopping 101 for Floor Drains</title>
      <link>https://staging-www.stifirestop.com/blog/news/firestopping-101-for-floor-drains</link>
      <description>&lt;p&gt;&lt;img class="wp-image-22445 alignleft" src="https://staging-www.stifirestop.com/hs-fs/hubfs/Imported_Blog_Media/Firestopping-101-for-Floor-Drains-1024x590.jpg?width=500&amp;amp;height=288&amp;amp;name=Firestopping-101-for-Floor-Drains-1024x590.jpg" alt="" width="500" height="288"&gt;Floor, shower and tub drains seem like fairly straightforward building features that don’t warrant a great deal of attention. Unfortunately, these types of drains can result in firestopping headaches for both manufacturers and installers. The test procedures can often be more rigorous relative to a regular through-penetration and the International Building Code (IBC) requires equal F and T Ratings since the drains are penetrants in a floor assembly.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;img class="wp-image-22445 alignleft" src="https://staging-www.stifirestop.com/hs-fs/hubfs/Imported_Blog_Media/Firestopping-101-for-Floor-Drains-1024x590.jpg?width=500&amp;amp;height=288&amp;amp;name=Firestopping-101-for-Floor-Drains-1024x590.jpg" alt="" width="500" height="288"&gt;Floor, shower and tub drains seem like fairly straightforward building features that don’t warrant a great deal of attention. Unfortunately, these types of drains can result in firestopping headaches for both manufacturers and installers. The test procedures can often be more rigorous relative to a regular through-penetration and the International Building Code (IBC) requires equal F and T Ratings since the drains are penetrants in a floor assembly.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Ffirestopping-101-for-floor-drains&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/firestopping-101-for-floor-drains</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>How do you refer to “firestop”?</title>
      <link>https://staging-www.stifirestop.com/blog/news/how-do-you-refer-to-firestop</link>
      <description>&lt;p&gt;For those of us who deal with firestopping every day, we sometimes take for granted that everyone intuitively&lt;img class="wp-image-21923 alignright" src="https://staging-www.stifirestop.com/hs-fs/hubfs/Imported_Blog_Media/10-Sealant-1024x740.jpg?width=339&amp;amp;height=245&amp;amp;name=10-Sealant-1024x740.jpg" alt="" width="339" height="245"&gt; understands this business we call firestopping. The vernacular can certainly vary at times, and that can add to the confusion. There are even colloquial ways that people use to refer to firestopping, such as the person I once encountered who called firestop caulk another term that might better be defined as the waste matter of primates. But I digress. This article is to shed some light onto the terminology that we use to describe firestopping.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;For those of us who deal with firestopping every day, we sometimes take for granted that everyone intuitively&lt;img class="wp-image-21923 alignright" src="https://staging-www.stifirestop.com/hs-fs/hubfs/Imported_Blog_Media/10-Sealant-1024x740.jpg?width=339&amp;amp;height=245&amp;amp;name=10-Sealant-1024x740.jpg" alt="" width="339" height="245"&gt; understands this business we call firestopping. The vernacular can certainly vary at times, and that can add to the confusion. There are even colloquial ways that people use to refer to firestopping, such as the person I once encountered who called firestop caulk another term that might better be defined as the waste matter of primates. But I digress. This article is to shed some light onto the terminology that we use to describe firestopping.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Fhow-do-you-refer-to-firestop&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/how-do-you-refer-to-firestop</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>What is the UL Technical Evaluation Developer Program (ULTEDP)?</title>
      <link>https://staging-www.stifirestop.com/blog/news/ul-technical-evaluation-developer-program</link>
      <description>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/ul-technical-evaluation-developer-program" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Screen-Shot-2023-05-11-at-3_35_26-PM.png" alt="What is the UL Technical Evaluation Developer Program (ULTEDP)?" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;div class="page"&gt; 
 &lt;div class="layoutArea"&gt; 
  &lt;div class="column"&gt; 
   &lt;p&gt;&lt;strong&gt;What is the UL Technical Evaluation Developer Program (UL TEDP) and what are the benefits that it will bring to the industry?&lt;/strong&gt;&lt;/p&gt; 
  &lt;/div&gt; 
 &lt;/div&gt; 
&lt;/div&gt;</description>
      <content:encoded>&lt;div class="hs-featured-image-wrapper"&gt; 
 &lt;a href="https://staging-www.stifirestop.com/blog/news/ul-technical-evaluation-developer-program" title="" class="hs-featured-image-link"&gt; &lt;img src="https://staging-www.stifirestop.com/hubfs/Imported_Blog_Media/Screen-Shot-2023-05-11-at-3_35_26-PM.png" alt="What is the UL Technical Evaluation Developer Program (ULTEDP)?" class="hs-featured-image" style="width:auto !important; max-width:50%; float:left; margin:0 15px 15px 0;"&gt; &lt;/a&gt; 
&lt;/div&gt; 
&lt;div class="page"&gt; 
 &lt;div class="layoutArea"&gt; 
  &lt;div class="column"&gt; 
   &lt;p&gt;&lt;strong&gt;What is the UL Technical Evaluation Developer Program (UL TEDP) and what are the benefits that it will bring to the industry?&lt;/strong&gt;&lt;/p&gt; 
  &lt;/div&gt; 
 &lt;/div&gt; 
&lt;/div&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Ful-technical-evaluation-developer-program&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/ul-technical-evaluation-developer-program</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
    <item>
      <title>New Firestop Systems – January 2020</title>
      <link>https://staging-www.stifirestop.com/blog/news/new-firestop-systems-jan-2020</link>
      <description>&lt;p&gt;New Fuel Pipe Protection with E-Wrap, Systems FP-3 and FP-4 –&amp;nbsp;Two new systems are available for the protection of fuel oil pipe using E-Wrap Endothermic Wrap. &lt;a href="https://files.stifirestop.com/1.%20System%20PDF%20Files%2F1.%20UL%20and%20cUL%20Systems%2Ffp3.pdf"&gt;FP-3&lt;/a&gt; is for a single pipe and &lt;a href="https://files.stifirestop.com/1.%20System%20PDF%20Files%2F1.%20UL%20and%20cUL%20Systems%2Ffp4.pdf"&gt;FP-4&lt;/a&gt; covers double containment piping applications. The testing to promulgate FP-3 and FP-4 was conducted in accordance with UL 1489 “Standard for Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids”. A through penetration firestop system for steel and iron pipes protected with E-Wrap passing through 2 Hr rated concrete walls and floors is addressed with &lt;a href="https://files.stifirestop.com/1.%20System%20PDF%20Files%2F1.%20UL%20and%20cUL%20Systems%2FCAJ5437_dl.pdf"&gt;C-AJ-5437&lt;/a&gt;.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;New Fuel Pipe Protection with E-Wrap, Systems FP-3 and FP-4 –&amp;nbsp;Two new systems are available for the protection of fuel oil pipe using E-Wrap Endothermic Wrap. &lt;a href="https://files.stifirestop.com/1.%20System%20PDF%20Files%2F1.%20UL%20and%20cUL%20Systems%2Ffp3.pdf"&gt;FP-3&lt;/a&gt; is for a single pipe and &lt;a href="https://files.stifirestop.com/1.%20System%20PDF%20Files%2F1.%20UL%20and%20cUL%20Systems%2Ffp4.pdf"&gt;FP-4&lt;/a&gt; covers double containment piping applications. The testing to promulgate FP-3 and FP-4 was conducted in accordance with UL 1489 “Standard for Fire Tests of Fire Resistant Pipe Protection Systems Carrying Combustible Liquids”. A through penetration firestop system for steel and iron pipes protected with E-Wrap passing through 2 Hr rated concrete walls and floors is addressed with &lt;a href="https://files.stifirestop.com/1.%20System%20PDF%20Files%2F1.%20UL%20and%20cUL%20Systems%2FCAJ5437_dl.pdf"&gt;C-AJ-5437&lt;/a&gt;.&lt;/p&gt;  
&lt;img src="https://track.hubspot.com/__ptq.gif?a=51149137&amp;amp;k=14&amp;amp;r=https%3A%2F%2Fstaging-www.stifirestop.com%2Fblog%2Fnews%2Fnew-firestop-systems-jan-2020&amp;amp;bu=https%253A%252F%252Fstaging-www.stifirestop.com%252Fblog&amp;amp;bvt=rss" alt="" width="1" height="1" style="min-height:1px!important;width:1px!important;border-width:0!important;margin-top:0!important;margin-bottom:0!important;margin-right:0!important;margin-left:0!important;padding-top:0!important;padding-bottom:0!important;padding-right:0!important;padding-left:0!important; "&gt;</content:encoded>
      <pubDate>Sat, 02 Mar 2024 05:00:00 GMT</pubDate>
      <guid>https://staging-www.stifirestop.com/blog/news/new-firestop-systems-jan-2020</guid>
      <dc:date>2024-03-02T05:00:00Z</dc:date>
      <dc:creator>Admin</dc:creator>
    </item>
  </channel>
</rss>
