3M - Fire Barrier Pass-Thru Device Square
SKU: PT4SD
Description:
3M Fire Barrier Pass-Through Device Square is a one-piece hinged metal enclosure designed to prevent the passage of fire, smoke, and toxic gas. This easily installed device is ideal for firestopping penetrations in high-traffic areas where telecom, data, or electrical cables are frequently added or removed. Intumescent material and foam smoke seals achieve a 3-hour fire protection rating.
Features (From 3M Website):
- Cable management solution for electrical, data, and communication applications
- One-piece, square-hinged metal enclosure makes installation fast and easy
- Intumescent material and foam smoke seals provide lasting firestop protection
- Square shape allows for stacking multiple boxes for ganging
- Re-enterable for high traffic areas or blank penetrations
- Firestop tested for up to 3 hours in accordance with ASTM E 814 (UL 1479)
Applications (From 3M Website):
- Cables — 750 kcmil, Cat 6, fiber optic, 300 pair No. 24 AWG copper telephone cable, thermostat
- Plastic pipes — ccPVC, PVC, ENT, CPVC, FRPP, PVDF, ccABS, ABS, rigid non-metallic, PEX
- Metal pipes — copper, steel, iron, flexible gas
- Insulated — AB/PVC on copper line sets
- Combinations — metallic, non-metallic, and insulated pipes plus cables
- Blank penetrations
Positioning:
- Cable management solution for electrical, data, and communication applications
Advantages:
- A self-sealing pathway to compete with EZ-Path
- Some tested systems include pipes as well as cables
Disadvantages:
- No ESR - No report from a Nationally Recognized Third-party Laboratory confirming the product is Maintenance Free, whereas EZ-Path is Inspection and Maintenance Free.
- No Custom Colors - There is no option for custom coloring at this time.
- Many customers of EZ-Path take advantage of this feature to color-code their pathway based on usage
- No Extension Modules - There is no ability to offer extension modules to accommodate thicker wall/floor assemblies.
- No Radius Control Module - There is no ability to offer a Radius Control Accessory. Although not impacting fire performance, this design consideration is considered an advantage by low-voltage contractors and designers.
- No Smoke & Acoustical Version - No capacity equivalent Smoke & Acoustical offering compromising the design of the overall cable pathway.
- No posted ASTM E90 STC Testing - No posted achievable STC Rating.
- All Fire-rated and Smoke & Acoustical EZ-Path Devices have STC Testing with results available upon request.
- Fewer sizes and configurations are available.
STI Product Cross
- EZ-Path Series 84+
- EZ-Path Series 44+
- EZ-Path Series 33
- EZ-Path Series 22
Product Literature