The Clinician Patient Access Device is a maintenance free self-sealing pass through for carrying patient services through corridor walls in Health care occupancies. The devices self-sealing membranes and intumescent technology automatically adjust as services are added or removed while still maintaining fire, smoke, and acoustical seals. Conserve Personal Protective Equipment (PPE) by carrying patient services from the corridor into the patient space while still meeting NFPA 101, HIPAA, and ADA Requirements.

Test Standards ASTM E90
ASTM E814 (UL1479)
Third Party Approvals

Features

  • Designed for temporary patient services in 1/2 hour rated Corridor Walls (per NFPA 101)
  • Self-sealing as services are added and removed
  • HIPAA and ADA Compliant
  • Clean appearance, blends seamlessly into room where aesthetics matter
  • Provides nursing staff with corridor access to patient rooms
  • Self-sealing; requires no action to provide a seal to reduce air flow, contamiN/Ants, or noise
  • Adjustable; accommodates corridor wall thickness 4” to 8” (102 to 203 mm)
Applications
Cables
Multiple Penetrations
Plastic Pipe
Properties
Finished Product
Intumescent
No Expiration
Paintable
Re-Enterable
STC Rating
Zero Maintenance
Smoke Barrier

Specifications

Property Value
Shell Composition Non-halogenated, V-0, ABS/PC Co-polymer and galvanized steel
Seal Low Smoke Silicone
Loading Area for Temporary Services 13.044 sq. in.
Allowable Fill 0 (empty) to 100% visual
In-Service Temperature -30°F to 130°F (-34°C to 54°C)
NFPA 101 Compliant for 1/2 Hour Rated Corridors Yes (Meets ASTM E814 (ANSI/UL1479))
Air Leakage Ratings Yes (Meets ANSI/UL1479 for L Ratings)
Acoustical (STC) Ratings Yes (Meets ASTM E90; Up to 50 STC dependent upon wall construction type and rating)
ADA Compliance Yes (Meets 2010 ADA Standards; No projection into corridor)
Cleaning/Sanitizing Products Household cleaners (e.g. Formula 409), Waterborne cleaners, Isopropyl alcohol sanitizing wipes,Steam sterilization (1x ok), Gamma/UV (may discolor plastic), Peracetic acid not recommended

Ordering Information

Catalog Number UPC Number Description (UOM) Qty. Case Qty. Weight (Each) Image
CPAD4K 730573009376 CP4K Clinical pass through device for 30 minute rated corridor walls with insertion tool 1 1 lbs CP4K Clinical pass through device for 30 minute rated corridor walls with insertion tool
CPADIT 730573009369 cpadit Insertion Tool for use with Clinician Patient Access Device 1 10 lbs
Clinician Patient Access Device
The Clinician Patient Access Device (CPAD) is a maintenance free self-sealing pass through for carrying patient services through corridor walls in Health care occupancies. The devices self-sealing membranes and intumescent technology automatically adjust as services are added or removed while still maintaining fire, smoke, and acoustical seals. Conserve Personal Protective Equipment (PPE) by carrying patient services from the corridor into the patient space while still meeting NFPA 101, HIPAA, and ADA Requirements.